TOPSOLAR® PV H1Z2Z2-K |
|
|
|
|
TÜV solar PV cable. |
|
|
|
|
|
BASED ON: |
EN 50618/ IEC 62930 / UTE C 32-502 |
|
|
|
|
|
|
|
|
DESIGN |
|
|
Conductor |
Class 5 (flexible) tinned copper, based on EN 60228 and IEC 60228. |
|
|
Insulation |
Low smoke zero halogen (LSHF) cross linked rubber insulation. |
|
|
|
Outer sheath |
Low smoke zero halogen (LSHF) cross linked rubber outher sheath, red or black colour. |
|
|
|
|
APPLICATIONS |
|
|
The Topsolar® PV H1Z2Z2-K cable, which is TÜV certified according to IEC 62930 and EN 50618, is suitable for both fixed and mobile solar installations (solar farms, rooftop solar installations and floating plants). It is a highly flexible cable compatible with all major connectors and specially desig- ned for the connection of photovoltaic panels. This versatile single-conductor cable is designed to meet the varying needs of the solar industry. Suitable for wet, damp and humid locations. |
|
|
|
|
|
|
FEATURES |
|
|
|
|
|
Electrical performance |
Low voltage 1,5/1,5 1kV (1,8) kV DC |
|
|
|
|
Based on |
EN 50618/ IEC 62930 / UTE C 32-502. |
|
|
|
|
Standards and approvals |
TÜV / RETIE / RoHS / CE. |
|
|
|
|
CPR (Construction Products Regulation) |
Cca -s1b, d2, a1. |
|
|
|
|
Thermal performance |
Maximum service temperature: 120°C. |
|
|
|
|
|
Maximum short-circuit temperature: 250°C (max. 5 s). |
|
|
|
|
Minimum service temperature: -40°C (fixed and protected installations). |
|
|
Fire performance |
Flame non-propagation based on EN 60332-1 and IEC 60332-1-2. |
|
|
|
Fire non-propagation based on EN 50399. |
|
|
|
|
|
Reaction to fire CPR: Cca -s1b, d2, a1, according to EN 50575. |
|
|
|
|
LSHF (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1. |
|
|
Low smoke emission based on EN 61034 and IEC 61034: Light transmittance > 60%. |
|
|
Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2 |
|
|
Mechanical performance |
Impact resistance: AG2 Medium severity. |
|
|
|
|
|
Minimum bending radius: x5 cable diameter. |
|
|
|
|
Chemical performance |
Chemical & Oil resistance: Excellent. |
|
|
|
|
|
Grease & mineral oils resistance: Excellent. |
|
|
|
|
|
UV Resistant based on EN 50618. |
|
|
|
|
|
Ozone resistant based on EN 50618. |
|
|
|
|
Water performance |
Water presence: AD8 submerged |
|
|
|
|
Other |
Meter by meter marking. |
|
|
|
|
|
Estimated lifetime 25 years based on EN 50618. |
|
|
|
|
|
Optional: rodent proof and termite proof. |
|
|
|
|
Installation conditions |
Open Air. |
|
|
|
|
|
Buried. |
|
|
|
|
|
On conduit. |
|
|
|
|
Packaging |
Available in rolls (lengths of 100 m) and reels. |
|
|
|
|